Media







Twenty-four high intensity lamps, arranged vertically, deliver a 30 to 40% boost in patient through-put while using half the space of conventional UVA1 units.
Twenty-four high intensity lamps, arranged vertically, deliver a 30 to 40% boost in patient through-put while using half the space of conventional UVA1 units.
The ML24000 uses a combination of high pressure lamps and special filters to produce an extremely pure UVA1 output, free of virtually all UVB content. This shortens treatment times and makes the use of medium and high dose protocols practical for the first time ever. A proprietary lamp and filtering system absorbs infrared output and limits spectral emission to the UVA1 range (340-400nm). High dose protocols can be delivered without the worry of UVB induced erythema as often seen in fluorescent UVA1 devices. Specially designed reflectors behind each of the twenty-four lamps diffuse the output and enhance the uniformity of therapeutic radiation to the patient. The ML24000 is operated by the time tested Daavlin Flex Controller, which can be remotely located for ease of physician access.
Conveniently located hand grasps make it easy to treat areas of the body that are normally difficult to expose. A built-in ventilation system keeps patients comfortable and maintains the lamps at their optimum operating temperature.
The unique, four column design of the ML24000 makes efficient use of valuable floor space. Requires half the space of typical lie-down models, and separates into modular sections for easy installation in small offices.
Treatments take significantly less time than those in conventional bed-type units, lessening patient fatigue and allowing you to see more patients. Patient through-put is increased by 30 to 40% due to high power output levels and 360 degrees of emission.
High dose protocols can be delivered without UVB induced erythema as seen with fluorescent UVA1 devices.
Conveniently located hand grasps make it easy to treat areas of the body that are normally difficult to expose.
Specially designed reflectors behind each of the twenty-four lamps diffuse output and enhance the uniformity of therapeutic radiation to the patient.
The unique, four column modular design makes efficient use of valuable floor space.
A built-in ventilation system keeps patients comfortable and maintains lamps at their optimum operating temperature.
The Daavlin Flex Controller can be remotely located for ease of physician access.
High dose protocols can be delivered without UVB induced erythema as seen with fluorescent UVA1 devices.
Conveniently located hand grasps make it easy to treat areas of the body that are normally difficult to expose.
Specially designed reflectors behind each of the twenty-four lamps diffuse output and enhance the uniformity of therapeutic radiation to the patient.
The unique, four column modular design makes efficient use of valuable floor space.
A built-in ventilation system keeps patients comfortable and maintains lamps at their optimum operating temperature.
The Daavlin Flex Controller can be remotely located for ease of physician access.
Depth | 62″ (158 cm) |
Width | 49″ (125 cm) |
Height | 98″ (249 cm) |
The following air movement facilities are required to be installed.
Diameter (Patient Cooling Ducts) | 2 x 8″ |
Diameter (Diameter Exhaust Duct) | 1 x 18″ |
3 x 120 volt lines plus ground line, 50/60 hz. 80 amp breaker 2 x 20.0 KVA buck/boosters Click HERE for ML24000 Product Brochure Click HERE to request detailed installation specifications